AEC-Q102较AEC-Q101增加的项目有哪些?

发布时间:2020-05-18 17:35:15
AEC-Q102较AEC-Q101增加的项目如下:
振动、冲击
VVF变频振动试验,试验条件:在20~100Hz频率范围内,位移幅值(峰-峰值)1.5mm;在100Hz~2kHz频率范围内,加速度200m/s2。
MS机械冲击,试验条件:X、Y、Z三个垂直轴的六个方向上各施加5次冲击(共30次),半正弦脉冲,持续时间0.5ms,峰值加速度1500g's
脉冲工作寿命PLT
脉宽100 μs,占空比3%
凝露DEW
温度循环范围为30~65℃,在65℃保持4~8 h,转换时间为2~4 h,RH=90~98%
以规格书中的最小驱动电流保持1008 h。若规格书中未定义额定最小电流,可选定一个驱动电流,其值不能使Tjunction的温度上升幅度超过3K。
硫化氢和混合气体腐蚀
H2S硫化氢腐蚀
在温度40℃和湿度90%RH的条件下保持336小时,H2S的浓度为15×10-6
FMG混合气体腐蚀
在温度25℃和湿度75%RH条件下保持500小时,气体浓度如下:
H2S浓度:10×10-9
SO2浓度:200×10-9
NO2浓度:200×10-9
Cl2浓度:10×10-9
AEC-Q102较AEC-Q101增加的项目条件一览表
Constant    Acceleration
CA
D,G,U,X
      (seq1)
10
3 Note B
0
MIL-STD-750-2
Method 2006
Only for Laser Component
Y1 plane only,15000 g-force.
TEST before and after CA.
Vibration Variable Frequency
VVF
D,G,U
      (seq2)
Items 14    through 17 are sequential tests(seq1 to seq4) for uncased packages
      (See Note U and H)
0
JEDEC
      JESD22-B103
Use a constant displacement of    1.5mm(double amplitude) over the range of 20 Hz to 100 Hz and a 200 m/s2 constant peak acceleration over the rang of 100Hz to 2 kHz.
TEST before and after VVF.
Mechanical Shock
MS
D,G,U
      (seq3)
0
JEDEC
      JESD22-B104
1500 g's for 0.5ms,5 blows,3 orientations.
TEST before and after MS.
Hermeticity
HER
D,G,H,X
      (seq4)
0
JEDEC
      JESD22-A109
Only for Laser Component
Fine and Gross leak test per individual user specification.
Pulsed Operating Life
PLT
D,G,X,Y
26
3
0
JEDEC
      JESD22-A108
Only for LED and Laser
Duration 1000 h at Tsolder=55℃
Operated with pulse width 100μs and duty cycle 3%.
Maximum pulse height according to part's specification.
TEST before and after PLT.
Dew
DEW
D,G
26
3
0
JEDEC
      JESD22-A100
T cycling 30-65℃ with dwell time at 65℃ between 4-8h,transition time between 2-4h; RH=90-98%
Duration 1008h with minimum drive current according to part    specification,If no minimum rated drive current is specified, a drive current shall be chosen not to exceed a rise of 3K for Tjunciton.
TEST before and after DEW.
Hydrogen Sulphide
H2S
D,G
26
3
0
IEC 60068-2-43
Duration 336 h at 40℃ and 90% RH.
H2S concentration:15x10-6
TEST before and after H2S.DPA after H2S.
Flowing Mixed Gas
FMG
D,G
26
3
0
IEC 60068-2-60
      Test method 4
Duration 500 h at 25℃ and 75%RH
H2S concentration:10x10-9
SO2 concentration:200x10-9
NO2 concentration:200x10-9
Cl2 concentration:10x10-9
TEST before and after FMG.DPA after FMG.
友情链接: